Troubleshooting Sflow Configuration; The Remote Sflow Collector Cannot Receive Sflow Packets - 3Com S7906E Configuration Manual

S7900e family release 6600 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

[Switch] sflow agent ip 3.3.3.1
# Specify the IP address and port number of the sFlow collector.
[Switch] sflow collector ip 3.3.3.2
# Set the sFlow interval to 30 seconds.
[Switch] sflow interval 30
# Enable sFlow in both the inbound and outbound directions on GigabitEthernet 2/0/1.
[Switch] interface GigabitEthernet 2/0/1
[Switch-GigabitEthernet2/0/1] sflow enable inbound
[Switch-GigabitEthernet2/0/1] sflow enable outbound
# Specify the traffic sampling rate.
[Switch-GigabitEthernet2/0/1] sflow sampling-rate 100000
# Display the sFlow configuration information.
[Switch-GigabitEthernet2/0/1] display sflow
sFlow Version: 5
sFlow Global Information:
Agent
Collector
Interval(s): 30
sFlow Port Information:
Interface
GE2/0/1

Troubleshooting sFlow Configuration

The Remote sFlow Collector Cannot Receive sFlow Packets

Symptom
The remote sFlow collector cannot receive sFlow packets.
Analysis
sFlow is not enabled globally because the sFlow agent or/and the sFlow collector is/are not
specified.
No port is enabled with sFlow to sample data.
The IP address of the sFlow collector specified on the sFlow agent is different from that of the
remote sFlow collector.
No IP address is configured for the Layer 3 interface on the device, or the IP address is configured,
but the UDP packets with the IP address being the source cannot reach the sFlow collector.
The physical link between the device and the sFlow collector fails.
Solution
1)
Check whether sFlow is correctly configured by displaying sFlow configuration with the display
sflow command.
2)
Check whether the correct IP address is configured for the device to communicate with the sFlow
collector.
3)
Check whether the physical link between the device and the sFlow collector is normal.