(9) Press the F1 key to display the following menu.
When inputting the recorded values
(10) If you have replaced the main board only, use the recorded values.
Press the F3 key (X=) to input the X of Tool Interval adjustment value.
Change the value by the UP ARROW key and the DOWN ARROW key.
The unit changes when the SLOW key was pressed.
Press the ENTER key to set value.
The following menu is displayed.
Press the F4 key (Y=) to input the Y of Tool Interval adjustment value.
Change the value by the UP ARROW key and the DOWN ARROW key.
The unit changes when the SLOW key was pressed.
Press the ENTER key to set value.
FCX2000-UM-251-9370
9
ELECTRICAL ADJUSTMENTS
9-29