(8) Disconnect the X Flexible Cable from the Y relay board.
(9) Detach the X Flexible Cable from the rear bottom cover.
How to reinstall the X Flexible Cable
(1) Prepare the following size of double-sided tapes when the X Flexible cable is going to replace.
One 10 x 30 mm double-sided tape
Three 10 x 26 mm double-sided tapes
(2) Fold the new X Flexible cable as shown in the picture below.
(3) Put the double-sided tapes to as shown in the picture below.
Mountain fold
This side has contact terminal.
77 mm
85 mm
115 mm
123 mm
258 mm
(4) Reattach the X flexible cable in the reverse order in which it was detached.
(5) Put the 10 x 26 double-sided tape to as shown in the picture below.
X flexible cable
Rear Y Slider
FCX2000-UM-251-9370
X flexible cable
Valley fold
Mountain fold
Valley fold
Valley fold
307 mm
317 mm
394 mm
8
Y relay board
Valley fold with right angle
Put the 10 x 25 mm Double-sided tapes to both side of here.
Put the 10 x 30 mm Double-sided tape to reverse side of here.
Double-sided tape
8-26
DISASSEMBLY AND ASSEMBLY
Valley fold with right angle
This side has contact terminal.
75 mm