USER'S GUIDE
IP RIP I
P
NPUT
ROCESSING ON A
Problem:
The SmartSwitch Remote Access Module does not display the correct route entry, for example, the
module does not seem to be learning route information via RIP.
Action:
1.
Verify that the IP RIP Receive Control is set to the proper RIP version that the Router is using.
Refer to
page 88
2.
Enter the ip rip stats administrative console command. Look for the counter
IfStatRcvResponses for the interface, which show the number of RIP update messages
received on the interface.
If the total number of these counters is 0, check the Router to verify that it is configured to send
IP RIP update messages.
3.
Also look for the IfStatRcvBadPackets and IfStatRcvBadRoutes counters.
If these counters are not 0, there may be something wrong with the Router.
If these counters are 0, there is an unexpected condition present within the SmartSwitch
Remote Access Module software. Contact Customer
IP RIP O
P
UTPUT
ROCESSING ON A
Problem:
The Router does not display the correct route entry, i.e., the Router does not seem to be learning
route information from the SmartSwitch Remote Access Module system via RIP.
Action:
1.
Verify that the IP RIP Send Control is set to the proper RIP version that the Router can
understand. Refer to page 88 for instructions regarding check RIP versions.
2.
Enter the ip rip interface administrative console command. Look for the Broadcast
Address value. This is the IP address of the router that the RIP messages are sent to.
If the address is not the correct address for the Router, correct the transmit broadcast address
for the interface using SFVRA-CFG. Refer to
address.
3.
Enter the ip rip stats administrative console command. Look for the IfStatSentResponses
counter for the interface, which shows the number of RIP update messages sent on the
interface.
If the counter is 0, enter the ip rip send administrative console command to force the RIP
update message to be sent immediately.
4.
Repeat step 3).
If the counter is still 0, there is an unexpected condition present within the SmartSwitch Remote
Access Module software. Contact Customer Support.
90
SmartSwitch Remote Access Module
LAN I
NTERFACE
for instructions regarding check RIP versions.
WAN I
NTERFACE
Support.
page 89