Cabletron Systems SmartSwitch 9W006 User Manual page 163

Remote access module
Hide thumbs Also See for SmartSwitch 9W006:
Table of Contents

Advertisement

S
M
YSTEM
ESSAGES
System Message Summary
If you are attempting remote analog console access, be sure to press the carriage return four times
within 5 seconds of making the connection.
Unable to get Digital Modem resource to place call
A Digital Modem dial-out call was attempted, and the system was unable to open a resource to
place the call. Using the modem status command, check to ensure that there are usable modems
available. If there are, and the problem persists, contact your Distributor or Customer Support.
Unable to Identify a remote device
A device that was not identified by any active security measures (for example, PAP or CHAP) was
rejected.
Unable to Identify a remote device - <calling line id
A device that was not identified by any active security measures (for example, PAP or CHAP) was
rejected and is identified by its Calling Line Id.
Unable to Identify a remote device - no CLID
A device that was not identified by any active security measures (for example, PAP or CHAP) was
rejected and the caller did not present a Calling Line Id.
Unable to identify the frame type <CCB: xxxx>
The frame type (raw HDLC, RFC 1294, or PPP) can not be identified and therefore the connection
has been terminated. "CCB: xxxx" is included for your Distributor or Customer Support. The most
likely causes for the problem are: malfunction of the remote device, or a faulty line. Begin by
checking the configuration of the remote device, and then rebooting the device. If this does not
solve the problem, contact your Distributor. He/she will help you determine whether or not the
line is faulty.
Unable to locate device entry in on-node database for terminal session
A device matching the login id entered at the user level security prompt was not found in the on-
node database, and SFVRA Connection Manager was not configured.
Unable to open \config\devdb.nei file
Disregard this message if you have not yet added at least one device to the system's on-node device
table and saved the change. The configuration file, \config\devdb.nei, is created the first time the
device table is saved. If the message continues, contact your Distributor or Customer Support.
Unable to open Modem Upgrade file
There may be a problem with the modem revision file. Contact your Distributor or Customer
Support.
Unable to restore original ISRs for Interrupt <interrupt # >
Check hardware jumpers and switches on the DM card and reinstall. Verify that the DM card is
properly configured in SFVRA-CFG. If the problem persists, contact your Distributor or Customer
Support.
Unable to send device information request to SFVRA after a terminal authentication.
Unable to send to SFVRA Connection Manager. Verify proper configuration of SFVRA-CONN and
Call Control options.