S
M
YSTEM
ESSAGES
System Message Summary
[IPX SAP] Unable to add service, service table full
The service table has become full. The maximum number of service entries should be increased.
Note:
This message will not recur in the log until space becomes available in the service table.
[IPXCP] Add Network Address to Pool with value above <network address>
This message informs the administrator that negotiation was not possible since non-convergence
was detected the network address sent by the peer was not acceptable by us and we do not have
any network address to assign to the peer. The possible remedy is to configure more IPX addresses
with a value more than <Network Address> in the Address Pool.
[IPXCP] IPX Address Match.
[IPXCP] Device <device> address same as another device address
The remote device indicated by <device> requested to use an already existing IPX network number
and node number.
[IPXCP] Our Node Address is <node address>
This message informs the administrator that the peer has assigned us a node number because the
system did not have a node address and the peer needs a node address. This node address will be
used by the peer to identify this system.
[IPXWAN] Master Slave Conflict. Change Internal Network Number above <present value>
This message indicates that over the IPXWAN link, the master and slave roles could not be
determined. The internal network number of the system must be changed to ensure proper
IPXWAN negotiation to occur.
[IPXWAN] IPX Internal Network Number must be configured.
You must configure a valid internal network number in order for IPX routing to work properly.
L3_CallRefSelect Call Reference wrapped
Status message indicating that Layer 3's call reference value has wrapped. If this message is posted
frequently, report the problem.
LAN Adapter Abort
The Ethernet adapter or subsystem is being interrupted as part of the error recovery process. If the
system fails to operate normally, or the warning continues to occur, then report the event using the
problem reporting form included in Getting Assistance.
LAN Adapter Command Timeout
The system expected a command from the LAN adapter or subsystem that it did not receive. Check
for proper LAN adapter configuration and hardware installation. If it persists, report the event
using the problem reporting form included in Getting Assistance.
LAN Adapter configuration conflict
There is a configuration conflict between the Ethernet resource that was installed and the Ethernet
resource that was configured. Correct the configuration to match the installation.
LAN Adapter Fatal Error Reported
LAN Adapter hardware failure detected. If the problem persists, replace your LAN adapter.