Restarting The Smartswitch Remote Access Module - Cabletron Systems SmartSwitch 9W006 User Manual

Remote access module
Hide thumbs Also See for SmartSwitch 9W006:
Table of Contents

Advertisement

USER'S GUIDE
1.
Refer to the illustration of the
2.
Insert the RJ-45 adapter at one end of the PRI cable into either the Mod-Tap adapter (U.S. and
Europe) or directly into the module's PRI port 1 (for all other installations).
3.
Insert the RJ-45 adapter at the other end of the PRI cable into your PRI service drop.
4.
Repeat steps 2 and 3 for PRI ports 2, 3, and 4 if applicable.
R
S
ESTARTING THE
The reset switch is a recessed switch located on the front panel, under the top-left plastic ejector tab
as illustrated below.
The reset switch serves two functions:
1.
Pressing the reset switch twice within three seconds causes the processor to reset.
2.
Pressing and holding the switch on for three or more consecutive seconds causes the module
to shutdown. Pressing and holding the switch again for three seconds restarts the module.
SNMP management may be used to disable this switch to enhance module security.
46
SmartSwitch Remote Access Module
9W0006-400
S
R
MART
WITCH
EMOTE
Power LED
SMB LED
for the PRI ports' locations.
A
M
CCESS
ODULE
Reset Switch
WAN
9W006-400