USER'S GUIDE
Negotiation Failure with Semipermanent device "x"
There was some problem negotiating a connection with device "x." There was no way to send data.
This could be an authentication failure or a PPP failure.
Network loop between site1 and site 2
The system detected a WAN loop between the specified sites, so the System will not forward the
duplicate frame. Check the System and network configuration for this loop and adjust.
Network requested init but no SPID configured- Slot=<slot # > Port=<port # > Ces=<communication
endpoint suffix>
A SPID is required but is not configured on the indicated line. The configuration of the SmartSwitch
Remote Access Module or of the switch should be corrected.
Network sent bad Endpoint identifier - Slot=<slot # > Port=<port # > Ces=<communication endpoint
suffix>
During terminal initialization, a bad endpoint identifier was received on the indicated line. This
message is informational only; your line should continue to operate normally.
Network sent CAUSE - invalid SPID - Slot=<slot # > Port=<port # > Ces=<communication endpoint
suffix>
An invalid SPID is configured on the indicated line. The configuration of the SmartSwitch Remote
Access Module or of the switch should be corrected.
Network sent Cause - SPID not supported - <slot # , port # >
The indicated line does not support SPIDs; however, a SPID is configured for use on the line. Is the
SPID configured incorrectly? Do you have the right switch type? Check the configuration. If the
message persists, contact your BRI provider to determine corrective action.
Network sent STATUS with state = 0, tear down call
A STATUS message has been received from the network indicating that a specified call is not active.
The system is removing the call.
No Active Calls
0 Active Sites
Currently, no sites are connected to the system.
No Active List entry available in INM
The system tried to contact a remote site and no table entries were available. You may need a larger
version of the SmartSwitch Remote Access Module.
No CCB found, Port=<port # >, CallRef=<call reference # >
Contact your Distributor or Customer Support. Provide your distributor with a copy of the
message log, and the output of the wan stats command. With the wan stats command, the
main item of interest is the "rcv fail" number on the connections line.
No compression sessions are available due to memory constraints.
Check available memory; upgrade to a 12Mb system (minimum). If you are still encountering
problems, disable unused protocols, and/or contact your Distributor or Customer Support to
reduce your number of available connections.
146
SmartSwitch Remote Access Module
Need help?
Do you have a question about the SmartSwitch 9W006 and is the answer not in the manual?
Questions and answers