System Message Summary
[SNMP] SNMP initialization failure - unable to allocate necessary memory
The SNMP feature was unable to initialize because it could not obtain the necessary memory. The
SNMP feature is disabled and no SNMP request will be processed. Contact your Distributor or
Customer Support.
[SNMP] SNMP initialization failure - unable to open UDP port
The SNMP feature was unable to initialize because it could not obtain the necessary UDP port. The
SNMP feature is disabled and no SNMP request will be processed. Check the configuration, and
then contact your Distributor or Customer Support.
[SNMP] SNMP initialized successfully
The SNMP Agent has been successfully initialized and is fully operational.
[SNMP] Unable to obtain an SNMP Trap queue entry buffer
The SNMP Agent attempted to generate a TRAP PDU but was unsuccessful because it could not
obtain necessary memory. The TRAP was not sent. Contact your Distributor or Customer Support.
[SNMP] Unable to obtain an SNMP Trap queue header
The SNMP Agent attempted to generate a TRAP PDU but was unsuccessful because it could not
obtain necessary memory. The TRAP was not sent. Contact your Distributor or Customer Support.
SPID FSM got unidentifiable INFO msg - Slot=<slot # > Port=<port # > Ces=<communication endpoint
suffix>
An unexpected information message was received from the network on the indicated line. If you
are having trouble establishing calls on this line, the problem should be reported to your phone
company.
SSB: Can't read RTC prior to i960 POSTs
The Real Time Clock became inaccessible before invoking the i960 POSTs. The RTC is used to guard
against infinite loops while waiting for the i960 to run its POST tests. The boot process should
continue; however, make note of the error message in the event of a future problem.
SSB: Couldn't read RTC during i960 POSTs
The Real Time Clock became inaccessible during the running of the i960 POSTs. The RTC is used
to guard against infinite loops while waiting for the i960 to run its POST tests. The boot process
should continue; however, make note of the error message in the event of a future problem.
SSB: i960 I/O memory copy differs from flash image at <address>
After loading the i960 POST tests into the I/O memory, a value unexpectedly changed at the
address given.
SSB: i960 Memory read error at <address>, expected <value>, read <value>
While testing the shared memory area (I/O memory and the peripheral buffer memory), an error
was detected. The boot process should continue; however, make note of the error message in the
event of a future problem.
SSB: i960 POST number not equal to i386's
The i386 requested the i960 to run a specific POST. Upon receiving the response, from the i960, it
was determined that a different POST was actually run.
The boot process should continue; however, make note of the error message in the event of a future
problem.