Error requesting slot activation
Contact your Distributor or Customer Support.
Error sending message to Call Control
The system detected a failure while sending a message to the WAN adapter. Restart the system and
review the resource configuration. If the error persists, contact your Distributor or Customer
Support.
Event <event code> occurred on FR Access <access index>, DLCI <dlci index>
A debug message logged to indicate Frame Relay events occurring for the indicated DLCI on the
indicated Access. The event is given in both textual, event, and numeric, code, forms.
Facility not subscribed - Slot=<slot # > Port=<port # >
This probably indicates a SPID configuration error on the indicated line. The configuration should
be corrected on the system or the switch.
Failed to allocate enough memory for XILINX load file
The WAN card initialization subsystem failed to allocate a buffer for use in downloading files.
Restart the system. If the problem continues, contact your Distributor or Customer Support.
FAILED TO BOOT SYSTEM SOFTWARE
While attempting to load the System software, an error was detected. The system will automatically
reset and attempt a reboot in an effort to correct the problem. If the system continues to fail, make
note of the displayed messages, and contact your Distributor or Customer Support. A software
update is likely needed.
FAILED TO FORMAT RFA
The Flash File System could not be formatted. The system will automatically reset and attempt a
reboot in an effort to correct the problem. If the system continues to fail, make note of the displayed
messages, and contact your Distributor or Customer Support. A software update is likely needed.
FAILED TO INSTALL XMODEM FILESET INTO FLASH MEMORY
While writing a file into the Flash File System, an error was detected. The system will automatically
reset and attempt a reboot in an effort to correct the problem. If the system continues to fail, make
note of the displayed messages, and contact your Distributor or Customer Support. A software
update is likely needed.
Failed to obtain Terminal info in smgr_proc_terminal_auth_sess 0
A session control block was not found for this authentication session. Contact your Distributor or
Customer Support.
Failed to start a Terminal Auth session. Device + User level Security not enabled
A terminal mode connection was received and Device + User level security was not enabled. Verify
correct security settings and default async protocol settings.
FAILED XMODEM INITIALIZATION
The UART controlling the Console Information Port (CIP) could not be initialized. The system will
automatically reset and attempt a reboot in an effort to correct the problem. If the system continues
to fail, make note of the displayed messages, and contact your Distributor or Customer Support. A
software update is likely needed.