Cabletron Systems SmartSwitch 9W006 User Manual page 198

Remote access module
Hide thumbs Also See for SmartSwitch 9W006:
Table of Contents

Advertisement

USER'S GUIDE
[System Name]> NEIF
id Name
-- ----
1
Ethernet Port 1
2
Ethernet Port 2
3
BRI.LINE.1
4
BRI.LINE.1
5
V.35.LINE
The definitions of the interface types and the associated status possibilities are as follows:
Ethernet
Each Ethernet port is considered an Ethernet interface. An Ethernet interface is "up" if the
Ethernet port is capable of forwarding packets to/from the LAN. An Ethernet interface is
"down" if the Ethernet port cannot be used to forward packets to/from the LAN.
Primary Rate (D-Channel)
Each Primary Rate line which contains at least one data link is considered a Primary Rate
(D-Channel) interface. A Primary Rate (D-Channel) interface is "up" if at least one data link
associated with the interface is "up." A Primary Rate interface is "down" if none of the data
links associated with the interface is "up."
Primary Rate (Robbed Bit)
Each Primary Rate line that uses Robbed Bit Signaling is considered a Primary Rate
(Robbed Bit) interface. A Primary Rate (Robbed Bit) interface is "up" if the serial layer 1 is
"up" for the line. A Primary Rate (Robbed Bit) interface is considered to be down if the
serial layer 1 is "down" for the line.
Primary Rate (Permanent)
Each Primary Rate line which is used by a dedicated access is considered a Primary Rate
(Permanent) interface. A Primary Rate (Permanent) interface is "up" if the serial layer 1 is
"up" for the line. The dedicated access does not have to be "up" for the interface to be
considered "up". A Primary Rate (Permanent) interface is considered to be down if the
serial layer 1 is "down" for the line.
sp
This command pertains to semipermanent connections. This command will list each
semipermanent device, as well as the connection status, initial data rate and current data rate
for each semipermanent device. The connection status will be one of the following:
C
ONNECTED
The system is connected to the device at the initial data rate or greater.
O
VERRIDDEN
The disc device command was issued on this device. The system will not attempt to call
again until a call device command is issued, or the system is rebooted.
N
C
OT
ALLABLE
This device cannot be called. Check phone number, device type or existence of the device name
in the database.
198
SmartSwitch Remote Access Module
Type
Slot
----
----
Ethernet
3
Ethernet
3
BRI D-Channel
1
BRI D-Channel
1
V.35
2
Port
Status
----
------
1
up
2
down
1
up
2
up
1
down

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartswitch 9w007

Table of Contents