Post <number>, ISDN Test FAILED
The specified D-channel controller, one of 4 2086 devices, did not pass its POST. The boot process
should continue; however, make note of the error message in the event of a future problem.
Post <number> memory read error at <address>, expected <value>, read <value>
The specified memory POST failed at the specified address, with both the expected and actual
memory values displayed. The boot process should continue; however, make note of the error
message in the event of a future problem.
Post <number> NVRAM Failure
The non-volatile RAM failed during its POST. The boot process should continue; however, make
note of the error message in the event of a future problem.
Post <number>, timed out waiting for i960 to respond during POSTs
The i960 failed to respond during the allotted amount of time during the specified POST. This is an
i960 failure. The boot process should continue; however, make note of the error message in the
event of a future problem.
[PPP] Link Failure Detected: No response to periodic Echo-Requests.
This message is logged by the feature when it detects a failed link.
PVC for DLCI <dlci index> not ACTIVE
A frame was received on the PVC associated with the indicated DLCI which was not active. This is
a temporary condition, and results from an asynchronous operation between the network and
customer-premise equipment regarding the state of the individual PVCs. If this problem persists,
contact your Distributor or Customer Support.
PVC not allocated for <dlci index>
The frame relay software received a frame from the network on PVC using the indicated DLCI
which has not yet been configured. It is likely that there is a configuration mismatch between nodes
in the network such that a node is transmitting data to the node logging this error via a valid but
as yet unallocated PVC.
PVC rcv wait q already full
Indicates a lack of system resources to handle the level of traffic being experienced. Contact your
Distributor or Customer Support.
RADIUS authentication is not available. You must first ENABLE RADIUS user level authentication.
An attempt was made to configure the Terminal Server Security for RADIUS and RADIUS was not
configured on the SmartSwitch Remote Access Module.
RBS: Channel <channel # > - Backing off of channel, GLARE detected.
An incoming and outgoing call occurred on the indicated channel at roughly the same time. The
system discontinued the outgoing call in order to allow the incoming call to be established.