OSW <OSWFileName>, found in the Flash File System. The OSW has not been updated from this file due
to insufficient Flash File System space. Please delete unnecessary files from the system.
Delete unneeded files to free up Flash File System space, and reboot the system. DO NOT DELETE
NEX.BIN, IOP.BIN, OR UPGRADE.BIN. The system will again attempt to install the compressed
file set after the system is rebooted again.
Outgoing calls barred - Slot=<slot # > Port=<port # >
The system cannot place outgoing calls on the indicated line. The switch must be configured to
handle circuit switched data calls. Contact your phone company and report the problem.
Out of CCBs, Port=<port # >, CallRef=<call reference # >
Contact your Distributor or Customer Support.
Out of LAN Adapter transmit command descriptors
The LAN adapter is temporarily out of buffers used to transmit frames on to the Ethernet. This
condition should clear. If it persists, contact your Distributor or Customer Support.
Out of overflow RAM buffers
Contact your Distributor or Customer Support.
Out Svc # <slot # , port # >
ISDN line failure. The line connected to the indicated slot and port is out of service for the reason
indicated by # .
1 = No layer 1 sync for 5 seconds
This problem normally occurs due to WAN cabling problems.
Check your cables to make sure they are connected correctly. If this problem still occurs
after you have checked all the cables, call the phone company and report the problem.
2 = No response to TEI requests
This problem normally occurs due to invalid configuration.
Check your configuration using the following table:
basic rate
line configured on non-
auto TEI
line configured on auto
TEI
3 = No UA response to SABME requests; no Layer 2
This problem normally occurs due to invalid configuration.
Check your configuration using the previous table.
4 = Failure to negotiate SPID (U.S. only). This is due to an improperly configured SPID. Check
your configuration.
148
SmartSwitch Remote Access Module
line from phone co:
point-to-point
make sure that the
configured TEI value
is 0
change TEI to be non-
auto
line from phone co:
multi-point
change TEI to be
AUTO
if problem happens
for over 5 minutes,
report problem to
phone company