the Radius Server report log for more information. If unsuccessful, contact your Distributor or
Customer Support.
[CHAP] Remote device indicates Authentication Failure of system <data>
The System received a fail reply in remote CHAP mode. This means that the System has not been
authenticated by the peer, and most likely the link will be released. <data> contains a portion of the
received frame, which should aid in trouble shooting the situation.
Circuit-mode/Packet-mode aggregation will not be allowed,
dropping oldest connection to site <site name>
This message may appear if switched calls are used to back up Frame Relay. If this message is seen
infrequently, it merely indicates the changeover from Frame Relay to switched calls and back again.
If this message is seen frequently, contact your Distributor. At the same time that these messages
are displayed in the log, an open Monitor Connection window may show brief periods (<1 second)
where the indicated Bandwidth suddenly increases and then decreases. This is due to the
changeover between Frame Relay and switched calls and is not a problem.
CNTR-TMR:Timed out waiting for TMR <number> interrupt!
The i386s specified timer did not respond during a POST testing its interrupt capabilities. The boot
process should continue; however, make note of the error message in the event of a future problem.
Configured adapter # 'x' type does not exist
The interface adapter indicated does not match the resource configuration in the system. Correct
the configuration on the system.
Connection disconnected for license violation
A connection was disconnected because there were more connections in place than allowed with
your version of the system software. A larger software version should be ordered.
Could not find port for static route with next hop address <AppleTalk Address>
Contact your distributor or Customer Support.
Could not get Call Restriction information
Contact your Distributor or Customer Support.
Could not get current monthly charges information
Could not get the current monthly call charge information on the system. The call charge feature
will be disabled and the problem should be reported. Contact your Distributor or Customer
Support.
Could not obtain fcr packet buffer
AppleTalk related. Contact your distributor or Customer Support.
Couldn't find speech service - <slot # , port # >
An incoming call was received which specified Speech Bearer Service capability. Speech service is
not currently supported with the System. Most likely, the incoming call was a wrong number. The
system will attempt to treat the call as 56 Kbps data.
Current monthly charges reset for new month
Reported on the first day of the month to indicate that the current monthly call charges value is
being reset to zero.