Remote Access Module). You can use this program to change Carbon Copy parameters such as
password, COM port, baud rate and modem type.
To change Carbon Copy parameters on the SmartSwitch Remote Access Module, terminate the
SmartSwitch Remote Access Module by typing quit . Next, enter the following command at the
MSDOS prompt to change the current directory to "ADMIN":
C:\>cd \admin
Enter the following command to start up the CCINSTAL program:
C:\admin>ccinstal
The Carbon Copy System Parameters screen will appear. Follow the directions on the screen to
change parameter settings.
A
Comm Port Address
B
Baud Rate
C
Modem Type
D
Keyboard Handling
E
Display Type
F
Menu Colors
G
Working Directory
H
Menu Level Option
1
CC Optional Configuration Parameters
2
CCHelp Optional Configuration Parameters
3
Call Table
4
Password Table
Type letter for selection:
After you make all parameter changes, select "X" to save the changes and exit the CCINSTAL
program. Restart the SmartSwitch Remote Access Module by issuing the command:
start_ne. After issuing the start_ne command, you must again login to the system.
CARBON COPY C
ONFIGURATION
If you wish to manage your SmartSwitch Remote Access Module via a modem, you will need to
make changes to the Carbon Copy configuration parameters. To make these configuration changes,
you must have previously installed your internal or external modem. You will also need a locally
attached keyboard and monitor.
To change Carbon Copy parameters on the SmartSwitch Remote Access Module, terminate the
SmartSwitch Remote Access Module by typing quit . Next, enter the following command at the
MSDOS prompt to change the current directory to "ADMIN":
C:\>cd \admin
Enter the following command to start up the CCINSTAL program:
C:\admin> ccinstal
The Carbon Copy System Parameters screen will appear. Refer to the above section titled
CARBON COPY Configuration Parameters
change parameter settings. The parameters that you may need to change are as follows:
COM1
9600
Direct Connect
USA Keyboard
Default
White on Blue
Default Directory
Advanced
P
ARAMETERS FOR
for a sample screen. Follow the directions on the screen to
Q
Quit, changes not saved
X
eXit, changes saved
M
U
ODEM
SAGE
R
M
EMOTE
ANAGEMENT
Carbon Copy
Changing
9W006 and 9W007
189