System Message Summary
NO FR LMI transmit buffer available
Indicates that, temporarily, no transmit buffer was available for formatting and sending a STATUS
ENQUIRY message to the network.
NO FR LMI transmit buffer descriptor available
Indicates that, temporarily, no transmit buffer descriptor was available for control and
administration of a STATUS ENQUIRY message to be sent to the network.
No internal b channel resources available, disconnecting call
The call is up, but there are no resources available to send the data. Contact your Distributor or
Customer Support.
No resources available to accept incoming call
The System received an incoming call, but it had already established the maximum number of calls.
This indicates the demand for network resources exceeds the configuration of this system. If this
type of occurrence continues, you should consider upgrading to a larger system.
No response to TEI requests - Slot=<slot # > Port=<port # > Ces=<communication endpoint suffix>
TEI configuration mismatch between the system and the switch for the indicated line. The
configuration of the system or of the switch should be corrected.
No Sites Connected
Currently, no sites are connected to the system.
Not enough memory for Security module
Not enough system memory available to operate security module. Contact your Distributor or
Customer Support.
No UA seen in response to SABMEs - Slot=<slot # > Port=<port # > Ces=<communication endpoint suffix>
Layer 2 cannot be established between the system and the switch. This could be a TEI configuration
mismatch between the system and the switch for the indicated line. Check the configuration of the
system. If this is not the problem, call your carrier. The configuration of the switch may need
correction, or the line may need to be manually restarted.
No VCB buffer available
Ran out of sending buffers for messages to Combinet. If this is a recurring problem, contact your
Distributor or Customer Support.
Number of optional connections reduced from xx to yy due to memory limitations
This informational message identifies that there is not enough memory available to accommodate
the system's total capacity load for optional connections.
Number of required connections reduced from xx to yy due to memory limitations
This informational message identifies that there is not enough memory available to accommodate
the system's total capacity load for required connections.
Offnode server lookup of Dial Out User failed.
Off-node authentication was not successful. Most likely, the device attempting to authenticate was
not configured. Check configuration.