c.
From the displayed list, double click on the site you are diagnosing.
d. Click on the Systems tab.
e.
Select the system in question then click on Edit System Settings.
f.
Under the IP information, check to make sure that a check appears next to Enable (IP
information is included under the Properties tab).
g. If you made a change, download the new configuration files to effected site.
For more detailed instructions, refer to the following sections in the SFVRA Configuration
Manager User's Guide:
For enabling IP routing: refer to Configuring the Site's Systems in the Configuring Sites
chapter.
For downloading configuration files: refer to Downloading Configuration Updates in the
Exporting Configuration Files chapter.
2.
The failure to see the following IP message for each IP interface:
[IP] Network initialized successfully on ddd.ddd.ddd.ddd
indicates that you may have either not configured a needed interface or have incorrectly
configured an interface. Check the system's IP network interface configuration using SFVRA-
CFG. If there are any problems, make the necessary corrections. To do this:
a.
If it is not already running, start up SFVRA-CFG.
b. From the toolbar, select Functions, then IP Network, then Systems, or click on the
c.
Select the system's site from displayed list.
d. Click on the Network Interface tab.
e.
Add any missing interfaces and/or make any necessary corrections to existing interfaces.
f.
If you made any changes, download the updated configuration files to the effected system.
For more detailed instructions, refer to the following sections in the SFVRA Configuration
Manager User's Guide:
For network interfaces: refer to Configuring IP Network System Interfaces in the Configuring
IP Network Information chapter.
For downloading updated configuration files: refer to Downloading Configuration Updates in
the Exporting Configuration Files chapter.
P
D
ROBLEM
IAGNOSIS
IP Routing Initialization
icon.
9W006 and 9W007
77