System Message Summary
5 = Failure to negotiate SPID (U.S. only). SPID has not been configured on the system; check
configuration.
Over Max Charge
Monthly call charges exceeded. Monthly call charge tracking is enabled and the configured
maximum has been exceeded.
[PAP] Identification timeout on remote device
The remote device did not send the PAP Authenticate-Request packet within a required amount of
time. Try again. If this persists, contact your remote site.
[PAP] Invalid password for <name> given by remote device
The system received the PAP Authentication-Request packet with the incorrect password for the
device name <name>.
[PAP] Remote device did not respond to the request
The system sent PAP Authenticate-Request packets the maximum number of times, but the remote
device did not send either Authenticate-Ack or Authenticate-Nak packets. The remote device may
not be working properly. Check the configuration of the remote device and reboot. If the problem
recurs, contact your Distributor or Customer Support.
[PAP] Remote device rejected System Information <error message>
The system received the PAP Authenticate-Nak packet with the error message <error message>
against the previous PAP Authenticate-Request sent by the system. The <error message> is from
the remote device, and is device-specific. Contact the remote site for assistance.
[PAP] Unknown name <name> given by remote device
The system received the PAP Authenticate-Request packet with the unknown device name
<name>.
Post <number>, HDLC # <number> External Loopback Test FAILED
The indicated HDLC controller, 80532 Device, failed an internal register test. The boot process
should continue; however, make note of the error message in the event of a future problem.
Post <number>, HDLC # <number> Internal Loopback Test FAILED
The indicated HDLC controller, 80532 Device, failed an internal loopback test. The boot process
should continue; however, make note of the error message in the event of a future problem.
Post <number>, HDLC # <number> Interrupt Test FAILED
The indicated HDLC controller, 80532 Device, failed an internal interrupt test. The boot process
should continue; however, make note of the error message in the event of a future problem.
Post <number>, HDLC # <number> Register Test FAILED
The indicated HDLC controller, 80532 Device, failed an internal register test. The boot process
should continue; however, make note of the error message in the event of a future problem.
Post <number>, HDLC # <number> Test FAILED
The indicated HDLC controller, 80532 Device, failed one of the constituent POSTs. The boot process
should continue; however, make note of the error message in the event of a future problem.