Semipermanent. Device "x" disconnected by admin
The administrator has issued a disc device <device name> command. Therefore, the system
will not attempt to call the indicated device again. Issuing the call device <device name>
command will make device "x" semipermanent again.
Semipermanent. Device "x" has a smaller Initial Data Rate than Base Data Rate. No connection made.
The semipermanent feature will make enough calls to meet but not exceed the device's Initial Data
Rate. In this case, the Base Data Rate (normally 56 or 64 Kbps) is larger than the device's Initial Data
Rate. The semipermanent feature cannot make any calls, or it will exceed the Initial Data Rate.
Reconfigure your data rates.
Semipermanent. Device "x" has had "y" bandwidth drops within "z" seconds. This device is considered to
have failed remote authentication.
Because the local system cannot always be aware of remote authentication failures, and because
there is no way to recognize remote authentication failures in the system once the remote end is
authenticated, the semipermanent feature will try to determine them by detecting excessive remote
bandwidth drops. The remote device must drop a call 10 times within a 10 minute period to trigger
this event.
Will try again in "w" minutes.
This will be displayed directly beneath the above message if a Session Interval is
configured for the device.
Semipermanent. Device "x" reconnected by admin.
The administrator has issued the call device <device name> command after issuing the
disc device <device name> command. This restarts the semipermanent feature for the
indicated device.
Severe congestion CLLM received for DLCI <dlci index>
A CLLM message was received indicating severe congestion may be expected on the PVC
associated with the indicated DLCI.
Signal for unknown CallCmd task: <task Id>
Contact your Distributor or Customer Support.
<slot # , port # > Cfg Error
Line vs. adapter configuration error. A line is configured for port <port # > that does not exist on
the adapter in slot <slot # >.
[SNMP] Authentication failure, improper access rights
There are two possible causes for this message:
The SNMP Agent received a SetRequest PDU that contained a Community Name with an MIB
access level of MIB GUEST or MIB USER. The MIB access level must be MIB ADMIN to per-
form a SetRequest. The request was discarded.
The SNMP Agent received a PDU that contained a Community Name with an MIB access level
of MIB GUEST and an object Id that cannot be accessed with an MIB GUEST access level. The
request was discarded.
[SNMP] Authentication failure, unknown community name
The SNMP Agent received a request PDU whose community name is not configured. The request
was discarded.