Cabletron Systems SmartSwitch 9W006 User Manual page 187

Remote access module
Hide thumbs Also See for SmartSwitch 9W006:
Table of Contents

Advertisement

The default file access for the GUEST user is "read" access to all files. The default file access for the
ADMIN user is "read" access to the report and statistics files, and "read and write" access to all
other files. The default for the TFTP server is ADMIN file access rights. The possible file types and
possible accesses for each user are:
Users
GUEST
ADMIN
where:
"R" for read only file access
"W" for write file access
"N" for no access rights for the corresponding file type
Actual files included in the file type categories are as follows:
File category
Report
Statistics
Configuration
Other
Note:
If you use TFTP to copy over configuration files to the SmartSwitch Remote Access
Module, the new configuration will not take place until the SmartSwitch Remote Access
Module is restarted. This may be accomplished with Telnet session and issuing the
restart command. The Telnet session must then be reestablished.
U
I
SAGE
NSTRUCTIONS
The SmartSwitch Remote Access Module has both the client and server TFTP components built into
it. When using the SmartSwitch Remote Access Module as the local client, enter the following
command(s) to transfer files:
tftp put
The tftp put command transfers files to the remote host; the tftp get command retrieves
files from the remote host. For either command you will then be prompted for the IP address of the
remote host, the complete path of local file name, the complete path of the remote file name, and
the file mode (binary or ASCII). You will be notified of the status of the transfer.
There is a tftp stats command that gives the user statistics on the TFTP feature. Statistics for
the server (or remote) side imply that someone from a remote device (either on the LAN or WAN)
initiated the request to transferred files to (or from) the SmartSwitch Remote Access Module.
Statistics for the client (or local) side imply that the user on the SmartSwitch Remote Access Module
initiated the request to transfer files to a remote device. The following statistics are available for
both the server and client sides:
Number of successful file puts
Number of successful file gets
Number of failed file puts
Number of failed file gets
Total bytes put
Total bytes get
Report Files
Statistics Files
RN
RN
RN
RN
File types included in the category
RPRT_LOG.1 - 10
STAT_LOG.1 - 10
*.NEI (with the exception of CFGTOKEN.NEI)
All other file types: .EXE, .COM, .TXT, (CFGTOKEN.NEI), etc.
or
tftp get
R
EMOTE
Config files
Other Files
RN
N
RWN
RWN
9W006 and 9W007
M
ANAGEMENT
TFTP
187

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartswitch 9w007

Table of Contents