To verify that IP routing has initialized properly:
1.
View the system messages. At the administration console type:
dr <return>
2.
Look for the following IP message among the system messages:
[IP] IP router is initialized successfully
3.
For each IP interface that has been configured, the following interface initialization message
should be displayed among the system messages.
[IP] Network initialized successfully on ddd.ddd.ddd.ddd
Note:
Other messages may also be displayed with the IP router initialization messages.
If you see these IP router initialization messages, then the IP router is operational. If these IP
router initialization messages are NOT displayed, refer to
Diagnosis chapter.
V
D
ERIFYING A
EDICATED
To verify a dedicated connection to the SmartSwitch Remote Access Module, the WAN lines that
are connected to the system must be available for use, and the routing option must be properly
initialized.
To verify that you have a dedicated connection:
1.
View the system messages by entering the following console command:
dr <return>
2.
Look for the following system message among the displayed messages:
Layer 1 sync not seen - Slot=<slot #> Port=<port #> Ces=<communication
endpoint suffix>
If the above message appears, a physical problem has been detected on the indicated line.
Check for a proper connection to the SmartSwitch Remote Access Module and to the NT1 or
CIU. If the NT1 or CIU appears to be functioning properly, call your carrier service and report
the problem.
If the above message does not appear in the displayed messages, proceed to the next step.
3.
Look for the following system message among the displayed messages:
Dedicated connection to device <device name> up: Slot=<slot#>,
Port=<port #>
If the above message is displayed, the dedicated connection is functioning.
If the following message appears, the dedicated connection is not functioning.
Dedicated connection down: Slot=<slot#>, Port=<port #>
56