S
M
YSTEM
ESSAGES
System Message Summary
Bad FR Frame Size = <frame size>
Indicates that a frame was received with an invalid length size. Contact your Distributor or
Customer Support.
Baud Rate is <value> bps
The Autobaud procedure has terminated and the RS232 port has been set to the specified baud rate.
[BIF] Could not allocate memory for buffer queue
[BIF] Initialization failed
These messages appear together in the report log. They indicate that an error occurred during
initialization of the Bridge Local Interface (which is required for IP Host mode). If these messages
are present in the log, the system will not operate correctly. Please contact your Distributor or
Customer Support.
Booting System Software
The Second Stage Boot is attempting to load and execute the System software.
Bootstrap came alive on DM card in slot <slot # >
Informational message stating that the initialization of the Digital Modem card was successful.
Bootstrap came alive on WAN card in slot <slot # >
Informational message during a successful system initialization. Download process update for
WAN card in slot <slot # >. This should be reported after the "Bootstrap loaded...waiting for
response" message for a given adapter.
Bootstrap loaded on WAN card in slot <slot # >, waiting for response...
Informational message during a successful system initialization. The first of three messages
providing the download process status for WAN card in slot <slot # >.
Bridge is operating in RESTRICTED mode
Bridge is operating in UNRESTRICTED mode
One of the above messages will be displayed to indicate the configured Bridge mode of operation.
Calculating CRC's.....
An X-Modem transfer has been completed and the received data is being checked for integrity.
Call control detected near end problem - Slot=<slot # > Port=<port # >
The system detected a problem when initiating a call over the indicated line. The call will be retried
over a different line if possible.
Calling Line ID Failure, Duplicate ID - <calling line Id>
A call has come in for a device that is using Calling Line Id (CLID) as the only authentication
method, and the given CLID is not unique across all devices.
Calling Line ID Security Failure <calling line Id>
The system has rejected a device due to a mismatch between the Calling Line Id presented by the
caller and the Calling Line Id in the on-node device database or obtained via an off-node
authentication server such as RADIUS.