Main control valve - Remove (Distributor assembly)
WARNING
Avoid injury!
Handle all parts carefully. Do not place your hands or fingers between parts. Use Personal Protec-
tive Equipment (PPE) as indicated in this manual, including protective goggles, gloves, and safety
footwear.
Failure to comply could result in death or serious injury.
1. Loosen the bolts (1) and remove distributor assembly
from lift housing.
NOTE: Distributor assembly is not serviceable. Replace
complete assembly if found defective.
2. Insert the distributor assembly back on the lift assembly
and tighten the bolts (1).
NOTE: Check the O-rings (1) for any damage on distributor
assembly before installing and replace if required.
Hydraulic systems - Main control valve
47866583_ 02/12/2015
35.7 [35.359] / 8
W0208A
1
GNIL14TR00798AA
2
GNIL14TR04649AB