New Holland WorkMaster 50 Service Manual page 726

Tier 4b (final)
Hide thumbs Also See for WorkMaster 50:
Table of Contents

Advertisement

DTC 2D3-12-ECU internal failure - Software resets in DSM 1 [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
DTC 2D4-04-ECU internal failure - ROM error [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
DTC 2E1-02-Starter relay low side driver circuit open [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
DTC 2E1-03-Starter relay low side driver circuit shorted to battery [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . 184
DTC 2E1-04-Starter relay low side driver circuit shorted to ground [ECU]. . . . . . . . . . . . . . . . . . . . . . . . . 186
DTC 2E1-12-Starter relay low side ECU driver circuit over temperature [ECU] . . . . . . . . . . . . . . . . . . . . 188
DTC 32B-02-Glow plug control circuits open [ECU]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
DTC 32B-03-Glow plug control circuits shorted to battery [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
DTC 32B-04-Glow plug control circuits shorted to ground [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
DTC 32B-12-Glow plug control circuits shorted [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
DTC 359-04-Fuel metering unit is shorted to ground at the low side [ECU] . . . . . . . . . . . . . . . . . . . . . . . 198
DTC 35A-03-Error in comparing energizing time to maximum value for injector in cylinder 2 [ECU] . . 200
DTC 35A-04-Error in comparing energizing time to minimum value for injector in cylinder 2 [ECU] . . . 201
DTC 35D-03-PMCat Inducement warning [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
DTC 37F-12-Missing adjustment value programming for injector in cylinder 3 [ECU] . . . . . . . . . . . . . . . 203
DTC 3C8-02-CAN communication failure between vehicle controller and ECU controller - TSC1_VE mes-
sage [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
DTC 3D4-02-ECU internal failure - ECU shutdown test failure [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
DTC 3D4-03-ECU internal failure - Wrong set response time [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
DTC 3D4-04-ECU internal failure - SPI errors during MoCSOP execution [ECU] . . . . . . . . . . . . . . . . . . 208
DTC 3D4-12-ECU internal failure - Loss of synchronization to MM from CPU [ECU] . . . . . . . . . . . . . . . 209
DTC 3E3-00-ECU internal failure - Fuel injection energizing time is not plausible [ECU] . . . . . . . . . . . . 210
DTC 3E3-01-ECU internal failure - Fuel injection energizing phase is not plausible [ECU] . . . . . . . . . . 211
DTC 3E3-02-Fuel injection correction has exceeded a minimum limit [ECU] . . . . . . . . . . . . . . . . . . . . . . 212
DTC 3E3-03-ECU internal failure - Injection quantity correction [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
DTC 3E3-04-ECU internal failure - Rail pressure plausibility [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
DTC 3E3-12-ECU internal failure - Torque request comparison [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
DTC 3F6-03-DOC inlet temperature sensor voltage is higher than expected [ECU] . . . . . . . . . . . . . . . . 216
DTC 3F6-04-DOC inlet temperature sensor voltage is lower than expected [ECU] . . . . . . . . . . . . . . . . . 218
DTC 426-03-Level 2 Monitoring : Reported Overvoltage of Supply [ECU] . . . . . . . . . . . . . . . . . . . . . . . . 220
DTC 426-04-Level 2 Monitoring : Reported Under Voltage of Supply [ECU]. . . . . . . . . . . . . . . . . . . . . . . 221
DTC 435-12-Rail pressure sensor value is intermittent [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
DTC 455-03-High pressure pump fuel delivery quantity at low idle is too high [ECU] . . . . . . . . . . . . . . . 224
DTC 459-03-Fuel metering unit intermittent electrical connection failure [ECU] . . . . . . . . . . . . . . . . . . . . 225
DTC 45A-03-Error in comparing energizing time to maximum value for injector in cylinder 3 [ECU] . . 227
DTC 45A-04-Error in comparing energizing time to minimum value for injector in cylinder 3 [ECU] . . . 228
DTC 48D-02-Throttle valve actuator control circuit open [ECU]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
DTC 48D-03-Throttle valve actuator control circuit over current [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
DTC 48D-12-Throttle valve actuator control circuit over temperature [ECU] . . . . . . . . . . . . . . . . . . . . . . . 233
DTC 4D4-03-ECU internal failure - Overvoltage monitoring error [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . 235
DTC 4D4-04-ECU internal failure - Undervoltage monitoring error [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . 236
DTC 4E3-03-ECU internal failure - Post injection quantity [ECU] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237