DTC 2E1-12-Starter relay low side ECU driver circuit over
temperature
Control Module : ECU
Context:
The Engine Control Unit (ECU) A-9000 controls the starter control relay K-9104 using a low side and high side driver.
If the ECU A-9000 detects an over temperature/current condition in the high side driver circuit, this fault will occur.
Cause:
The ECU A-9000 has detected an over temperature/current condition in the starter control relay K-9104 high side
driver circuit.
Possible failure modes:
1. Faulty starter control relay K-9104 wiring, short circuit.
2. Faulty starter control relay K-9104, internal failure.
3. Faulty ECU A-9000, software.
Solution:
1. Verify fault is present and active.
Use the Electronic Service Tool (EST) to check the status of this fault.
A. If the fault is present and active, continue with Step 2.
B. If the fault is no longer present or in an inactive state, the fault may be intermittent and not currently active.
Continue with Step 6.
2. Check the starter control relay K-9104 coil for an internal failure.
Remove the starter control relay K-9104.
Use a multimeter to measure the relay coil resistance on the starter control relay K-9104 pins :
From
X-9120 pin 85
A. If there is approximately 70 - 130 Ω, leave the starter control relay K-9104 disconnected and continue to Step
3.
B. If there is not approximately 70 - 130 Ω, the relay has failed. Replace the starter control relay K-9104.
3. Check the starter control relay K-9104 high side driver vehicle harness (VE) wiring for a short to ground.
With the key in the OFF position, use a multimeter to perform the following continuity check for short to ground on
the vehicle harness (VE) side :
From
X-9120 pin 85
X-9120 pin 86
A. If there is continuity, there is a short to ground in the starter control relay K-9104 high side driver circuit in
the vehicle harness (VE). Use the appropriate service manual, if necessary, to locate and repair the shorted
conductor.
B. If there is no continuity, leave the starter control relay K-9104 disconnected and continue to Step 4.
4. Check the starter control relay K-9104 high side driver vehicle harness (VE) wiring for a short to a voltage source.
Electrical systems - FAULT CODES
To
X-9120 pin 86
To
X-9120 pin 86
Chassis ground
47866583_ 02/12/2015
55.12 [55.DTC] / 188
Value
There should be approximately 70 -
130 Ω.
Value
There should be no continuity.
There should be no continuity.