DTC 2CC-01-Engine controller internal temperature out of range
(Low)
Control Module : ECU
Context:
The Engine Control Unit (ECU) A-9000 has an internal temperature sensor. The ECU A-9000 monitors this sensor.
If the ECU A-9000 determines that the temperature sensor value is too low, this fault will occur.
Cause:
The ECU A-9000 has determined that the internal ECU A-9000 temperature sensor value is too low.
Possible failure modes:
1. Machine is operating in extreme environmental conditions.
2. Faulty ECU A-9000, software.
Solution:
1. Check the ECU A-9000 for the appropriate software and re-flash, if necessary.
A. If the fault has been resolved, return the machine to service.
B. If the fault has not been resolved, escalate an ASIST concern.
Electrical systems - FAULT CODES
47866583_ 02/12/2015
55.12 [55.DTC] / 177