New Holland WorkMaster 50 Service Manual page 409

Tier 4b (final)
Hide thumbs Also See for WorkMaster 50:
Table of Contents

Advertisement

Main lift system - Disassemble
WARNING
Avoid injury!
Handle all parts carefully. Do not place your hands or fingers between parts. Use Personal Protec-
tive Equipment (PPE) as indicated in this manual, including protective goggles, gloves, and safety
footwear.
Failure to comply could result in death or serious injury.
NOTE: Draft sensing unit and related external linkages can be disassembled and assembled with the lift unit mounted
on the tractor.
Draft sensing unit - Removal
1. Loosen the bolts (1) from the sensing unit.
2. Remove the lock (1) and remove draft link (2).
3. Loosen bolts (1) and set screw.
4. Remove the pin as shown in figure.
5. Remove the sensing unit from the lift housing.
Hydraulic systems - Main lift system
47866583_ 02/12/2015
35.2 [35.100] / 14
W0208A
1
GNIL14TR04617AB
2
GNIL14TR04618AB
3
GNIL14TR04619AB