DTC 5D4-03-ECU internal failure - Alarm task period error
Control Module : ECU
Context:
The Engine Control Unit (ECU) A-9000 performs "shut-off paths" which deactivate all power stages relevant to fuel
injection if certain ECU A-9000 errors are detected. If an alarm task can not be set or reset after having detected a
time-out error during this test, this fault will occur.
Solution:
1. Check the ECU A-9000 for the appropriate software and re-flash, if necessary.
A. If the fault has been resolved, return the machine to service.
B. If the fault has not been resolved, escalate an ASIST concern.