Non-powered front axle - Troubleshooting
Problem
Premature tire wear
Poor tractor stability
Front axle system - Non-powered front axle
Possible Cause
Wrong inflation pressure
Wrong front wheel toe-in
Wrong inflation pressure
47866583_ 02/12/2015
25.5 [25.400] / 18
Correction
Inflate tyres to correct pressure refer to val-
ues suggested in the operator's manual.
Always comply with values specified by the
tire manufacture
Adjust toe-in (see the procedure explained
in this section under adjustment)
Inflate tyres to correct pressure