Delay Off and Low Power Detection
In this example, the surveillance system on the bus will transmit video files back to the back-end server when the bus returns
to the depot. The driver will shut the bus off and leave the bus parked in the depot, but the uplink connection for the
surveillance system still needs to be available until all video files are completely uploaded. Usually, video files on each bus
can be uploaded completely within 15 minutes. To prevent draining the battery, the bus driver activates the low voltage
detection function to force the router to shut down if the battery voltage reaches 22V (regular voltage is 24V).
To make the router ignition-dependant select Power Control from the Service menu. The Ignition Sense tab will display.
Attention – The Ignition Sense feature is  disabled by default.
When  enabled, the router will not power on until power from the ignition pin of its terminal block is detected (ACC ON).
Item
Ignition Sense
NTC-400 Series
Figure 401 – Ignition Sense configuration
Figure 402 – Ignition Sense Example
Figure 403 – Ignition Sense configuration
Notes
Description
Click  Enable to activate the Ignition Sense function.
Disabled by default.
By default, the function is disabled, and the router will be
always ON when the power source is attached.
341 of 359