When Add button is applied, the Digital Output (DO) Profile Configuration screen will appear.
Item
DO Profile
Mandatory field.
Name
String format.
Description
Optional field.
Any text.
DO Source
Default setting: ID1
Normal Level
Default setting: Low
Total Signal Period
Mandatory field.
Numeric String format
Repeat & Counter
Disabled by default.
Duty Cycle
Mandatory field.
Numeric String format
Profile
Disabled by default.
Save
Button
8.2.2
Managing Events
Managing Events allow administrator to define the relationships (rules) between event triggers, handlers and responses.
328 of 359
© NetComm Wireless 2019
Figure 386 – Digital Output (DO) Profile List
Figure 387 – Digital Output (DO) Profile Configuration
Notes
Specify the DO Profile Name.
Value Range: -1 - 32 characters.
Write a brief, meaningful description of the profile.
Specify the DO Source as ID1.
Specify the Normal Level: Low or High
Specify the Total Signal Period.
Value Range: 10 - 10000 ms.
Click Enable to activate the repeated Digital Output, and
specify the Repeat times.
Value Range: 0 - 65535.
Specify the Duty Cycle for the Digital Output.
Value Range: 1 - 100 %
Click Enable to activate this profile setting.
Click the Save button to save changes to the configuration.
Table 240 – Digital Output (DO) Profile Configuration
Description
User Guide