File Copy Setting Fault Description:
These faults will happen when KPC-CC01 cannot perform the command after clicking the Enter button in
copy function.
LCM Display *
Description
Parameter and file are read only
Fail to write parameter and file
AC drive is in operating status
AC drive parameter is locked
AC drive parameter changing
Fault code
Warning code
File type dismatch
Chapter 10 Digital KeypadC2000-HS
Corrective Actions
The property of the parameter / file is read-only and
cannot be written to.
1. Verify the specification on the user manual.
If the solution above doesn't work, contact your local
authorized dealer.
An error occurred while writing to a parameter / file.
1. Verify if there's any problem on the Flash IC.
2. Shut down the system, wait for ten minutes, and
then power on again the system.
If none of the solution above work, contact your local
authorized dealer.
A setting cannot be made while motor drive is in
operation.
1. Verify if the drive is not in operation.
If the solution above doesn't work, contact your local
authorized dealer.
A setting cannot be made because a parameter is
locked.
1. Verify if the parameter is locked or not. If it is locked,
unlock it and try to set up the parameter again.
If the solution above doesn't work, contact your local
authorized dealer.
A setting cannot be made because a parameter is
being modified.
1. Verify if the parameter is being modified. If it is not
being modified, try to set up that parameter again.
If the solution above doesn't work, contact your local
authorized dealer.
A setting cannot be made because an error has
occurred on the motor drive.
1. Verify if there's any error occurred on the motor
drive. If there isn't any error, try to make the setting
again.
If the solution above doesn't work, contact your local
authorized dealer.
A setting cannot be made because of a warning
message given to the motor drive.
1. Verify if there's any warning message given to the
motor drive.
If the solution above doesn't work, contact your local
authorized dealer.
The copied data are not the same type, so the setting
cannot be made.
1. Verify if the products' serial numbers need to be
copied fall in the category. If they are in the same
category, try to make the setting again.
If the solution above doesn't work, contact your
authorized dealer.