Chapter 12 Description of Parameter SettingsC2000-HS
Homing by Frequency 1
Settings
Homing by Frequency 2
Settings
 Controlled by multi-function input terminal Pr. 02-01–02-08 (44–47).
44: Reverse direction homing (NL)
45: Forward direction homing (PL)
46: Homing (ORG)
47: Homing function enabled
 If the drive is not controlled by CANopen or the PLC, when setting Pr. 00-10 = 1 (Control mode =
P2P position control), set the external input terminal to 47 (homing function enable) for homing.
 When Pr. 00-10 is set to 3, after homing is complete, you must set the control mode (Pr. 00-10=1)
to execute P2P position control.
Display Filter Time (Current)
Settings
 Minimizes the current fluctuation displayed by digital keypad.
Display Filter Time (Keypad)
Settings
 Minimizes the value fluctuation displayed by digital keypad.
Software Version (date)
Settings
 Displays the current drive software version by date.
0.0–1500.0 Hz
0.0–1500.0 Hz
0.001–65.535 sec.
0.001–65.535 sec.
Read only
12.1-00-20
Default: 8.0
Default: 2.0
Default: 0.100
Default: 0.100
Default: Read only