Delta VFD300C43S-HS User Manual page 546

Vector control drive (high speed models)
Table of Contents

Advertisement

Chapter 13 Warning CodesC2000-HS
ID No.
Display on LCM Keypad
77
Action level
Action time
Warning setting parameter
Reset method
Reset condition
Record
Cause
The cable is loose
Incorrect parameter setting for
master communication
ID No.
Display on LCM Keypad
78
Action level
Action time
Warning setting parameter
Reset method
Reset condition
Record
Cause
The GSD file is incorrect
ID No.
Display on LCM Keypad
79
Action level
Action time
Warning setting parameter
Reset method
Reset condition
Record
Cause
The GSD file is incorrect
Warning Name
ExCom IO Net break
IO connection break off
(ECio)
Action and Reset
IO connection between the communication card and the master is broken off
Immediately acts
N/A
Manual reset
Immediately reset
N/A
Re-install the cable
Check the setting for master communication parameter
Warning Name
ExCom Parameter
data error
Profibus parameter data error
(ECPP)
Action and Reset
N/A
N/A
N/A
Manual reset
Immediately reset
N/A
Get the correct GSD file from the software
Warning Name
ExCom configuration
data error
Profibus configuration data error
(ECPi)
Action and Reset
N/A
N/A
N/A
Manual reset
Immediately reset
N/A
Get the correct GSD file from the software
13-34
Description
Corrective Actions
Description
Corrective Actions
Description
Corrective Actions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents