Modbus
RW
address
2205H
R
Power angle (XXX.X)
2206H
R
Display actual motor speed kW of U, V, W (XXXXX kW)
Display motor speed in rpm estimated by the drive or encoder feedback
2207H
R
(XXXXX rpm)
Display positive/negative output torque in %, estimated by the drive (t0.0:
2208H
R
positive torque, -0.0: negative torque) (XXX.X %)
2209H
R
Display PG feedback (see NOTE 1 in Pr. 00-04)
220AH
R
PID feedback value after enabling PID function (XXX.XX %)
Display signal of AVI analog input terminal, 0–10V corresponds to
220BH
R
0.00–100.00% (1.) (see NOTE 2 in Pr. 00-04)
Display signal of ACI analog input terminal, 4–20mA / 0–10V corresponds to
220CH
R
0.00–100.00% (2.) (see NOTE 2 in Pr. 00-04)
Display signal of AUI analog input terminal, -10V–10V corresponds to
220DH
R
-100.00–100% (3.) (see NOTE 2 in Pr. 00-04)
220EH
R
IGBT temperature of drive power module (XXX.X ºC)
220FH
R
The temperature of capacitance (XXX.X ºC)
The status of digital input (ON/OFF), refer to Pr. 02-12
2210H
R
(see NOTE 3 in Pr. 00-04)
The status of digital output (ON/OFF), refer to Pr. 02-18
2211H
R
(see NOTE 4 in Pr. 00-04)
2212H
R
The multi-step speed that is executing (S)
The corresponding CPU pin status of digital input (d.)
2213H
R
(see NOTE 3 in Pr. 00-04)
The corresponding CPU pin status of digital output (O.)
2214H
R
(see NOTE 4 in Pr. 00-04)
Number of actual motor revolution (PG1 of PG card) (P.) it starts from 9
2215H
R
when the actual operation direction is changed or the keypad displays at
stop is 0. The maximum is 65535
2216H
R
Pulse input frequency (PG2 of PG card) (XXX.XX Hz)
2217H
R
Pulse input position (PG card PG2), the maximum setting is 65535.
2218H
R
Position command tracing error
2219H
R
Display times of counter overload (XXX.XX %)
221AH
R
GFF (XXX.XX %)
221BH
R
DCBUS voltage ripples (XXX.X V)
221CH
R
PLC register D1043 data (C)
221DH
R
Number of poles of a permanent magnet motor
221EH
R
User page displays the value in physical measure
221FH
R
Output Value of Pr. 00-05 (XXX.XX Hz)
Number of motor turns when drive operates (saves when drive stops, and
2220H
R
resets to zero when operating)
Operating position of the motor (saves when drive stops, and resets to zero
2221H
R
when operating)
2222H
R
Fan speed of the drive (XXX %)
2223H
R
Control mode of the drive 0: speed mode 1: torque mode
2224H
R
Carrier frequency of the drive (XX kHz)
2225H
R
Reserve
2226H
R
Drive
status
00b: No direction
bit1–0
01b: Forward
10b: Reverse
bit3–2
01b: Drive ready
10b: Error
bit4
0b: Motor drive did not output
1b: Motor drive did output
12.1-09-10