8-15-4 RJ45 PIN Definition
RJ45
8-15-5 Communication Parameters for VFD-C2000-HS Connected to EtherCAT
When operating VFD-C2000-HS via CMC-EC01, please set the control and operation command
as controlled by communication card. When C2000-HS is connected to EtherCAT network, set up
the communication parameters according to the table below.
Parameter
Pr. 00-20
Pr. 00-21
Pr. 09-60
Pr. 09-61
8-15-6 LED Indicator
LED
POWER
LINK
ESD (IEC 61800-5-1, IEC 61000-4-2)
EFT (IEC 61800-5-1, IEC 61000-4-4)
Surge Test (IEC 61800-5-1, IEC 61000-4-5)
Conducted Susceptibility Test (IEC 61800-5-1, IEC 61000-4-6)
-10°C–15°C (temperature), 90% (humidity)
-25°C–70°C (temperature), 95% (humidity)
International standard: IEC 61800-5-1, IEC 60068-2-6 / IEC 61800-5-1,
IEC 60068-2-27
PIN No.
Signal
1
Tx+
2
Tx-
3
Rx+
4
--
5
--
6
Rx-
7
--
8
--
Set value (Dec)
8
The frequency command is controlled by communication card.
5
The operation command is controlled by communication card.
Identification: when CMC-EC01 is connected, Pr.09-60 will show
6
value 6 (EtherCAT Slave)
--
Version of communication card
Status
Green
Green
Flashes
Positive pole for data transmission
Negative pole for data transmission
Positive pole for data receiving
N / C
N / C
Negative pole for data receiving
N / C
N / C
Explanation
ON
Power supply in normal status
OFF
No power supply
ON
Operate in normal status
Pre-operation (ON / OFF 200ms)
Operate in safe mode
(ON 200ms / OFF 1000ms)
OFF
Initial state
8-39
Chapter 8 Option CardsC2000-HS