Delta VFD300C43S-HS User Manual page 223

Vector control drive (high speed models)
Table of Contents

Advertisement

Pr.
Parameter Name
00-32
Digital keypad STOP function
00-40
Homing mode
00-41
Homing by frequency 1
00-42
Homing by frequency 2
00-48
Display filter time (current)
Chapter 11 Summary of Parameter SettingsC2000-HS
Setting Range
2: RS-485 communication.
3: CANopen communication card
5: Communication card (does not include CANopen
card)
0: Disable STOP key
1: Enable STOP key
Note: Forward run = clockwise (CW)
Reverse run = counterclockwise (CCW)
0: Forward run to home.
Set PL forward limit as check point.
1: Reverse run (CCW) to home.
Set NL reverse limit (CCWL) as check point.
2: Forward run to home. Set ORG:
OFF → ON as check point.
3: Reverse to home. Set ORG:
X
OFF → ON as check point.
4: Forward run and search for Z-pulse as check
point.
5: Reverse run and search for Z-pulse as check
point.
6: Forward run to home. Set ORG:
ON → OFF as check point.
7: Reverse run to home. Set ORG:
ON → OFF as check point.
8: Define current position as home.
Set X to 0, 1, 2, 3, 6, 7 first.
0: Reverse run to Z pulse
Y
1: Continue forward run to Z pulse
2: Ignore Z pulse
When home limit is reached, set X to 2, 3, 4, 5,
6, 7 first.
Z
0: Display the error
1: Reverse the direction
0.0–1500.0 Hz
0.0–1500.0 Hz
0.001–65.535 sec.
11-7
Default
0
0000h
8.0
2.0
0.100