Induction motor system inertia (unit: kg-cm
Rated power
[HP]
[kW]
30
22
40
30
50
37
60
45
75
56
100
75
120
89
The base value for PM system inertia is set by Pr.05-38 and the unit is in kg-cm
ASR1 / ASR2 Switch Frequency
Settings
The upper limit is the same as the maximum operation frequency for Pr.01-00.
Sets the low-speed and high-speed ASR switching point in the FOC area. Provides flexibility to
meet two needs: in the high-speed region of the estimator switch point it has a high response,
and in the low-speed region of the estimator switch point it has a lower response. The
recommended switching point is higher than Pr.10-39.
A low setting does not cover Pr.10-39. If the setting is too high, the high-speed range is too
narrow.
ASR1 Low-speed Bandwidth
Settings
ASR2 High-speed Bandwidth
Settings
Zero-speed Bandwidth
Settings
 After estimating inertia and setting Pr.11-00 bit0=1 (auto-tuning), you can adjust Pr.11-03,
Pr.11-04 and Pr.11-05 separately according to the speed response. The larger the setting value,
the faster the response. Pr.11-02 is the switch frequency for the low-speed / high-speed
bandwidth.
 The position control pulse command (MIx=37) and P2P position control Kp gain can adjust
Pr.11-05. The higher the value, the lower the steady-state error.
ASR 1 Gain
Settings
Rated power
Inertia
[HP]
[kW]
17.6
150
20.2
175
35.5
215
41.0
250
49.4
300
105.6
375
127.5
420
5.0–1500.0 Hz
1–40Hz (IM) / 1–100Hz (PM)
1–40Hz (IM) / 1–100Hz (PM)
1–40Hz (IM) / 1–100Hz (PM)
0–40 Hz (IM) / 1–100Hz (PM)
Chapter 12 Description of Parameter SettingsC2000-HS
2
):
Inertia
112
190.0
130
215.0
160
280.0
186
355.0
224
513.9
279
598.1
313
705.3
12.1-11-4
Rated power
Inertia
HP
kW
475
354
964.3
535
399
1073.4
2
.
Default: 7.0
Default: 10
Default: 10
Default: 10
Default: 10