Chapter 16 PLC Function ApplicationsC2000-HS
API
SIN
130
D
Bit device
X
Y
S
D
Notes on operand usage:
Please refer to the function specifications table for each device in series
for the scope of device usage
S: the designated source value. D: the SIN value result.
S is the designated source in radians.
The value in radians (RAD) is equal to (angle ×π/180).
The SIN obtained from the source value designated by S is stored in D.
The following figure displays the relationship between the arc and SIN results:
When X0=On, the SIN value of the designated binary floating point number (D1,
D0) in radians (RAD) will be stored in (D11, D10), with the content consisting of a
binary floating point number.
X0
P
Word device
M
K
H
KnX KnY KnM
*
*
DSIN
D0
Binary floating point number SIN operation
16-bit command
T
C
D
*
32-bit command (9 STEP)
*
DSIN
execution type
Flag signal: none
D10
16-90
Continuous
DSINP
execution type
Pulse