Example: Crane Application
It is recommended to use with Dwell function as shown in the following:
Chapter 12 Description of Parameter SettingsC2000-HS
To control output of CANopen & InnerCOM internal
communication.
Status of
the drive
Status A (MOx=66)
Normal
Broken circuit (Open)
STO
Short circuit (Close)
STL1–STL3
Short circuit (Close)
The multi-function output terminals operate when the analog input
level is between the high level and the low level.
Pr.03-44: Select one of the analog input channels (AVI, ACI and
AUI) to be compared.
Pr.03-45: The high level for the analog input, default is 50%.
Pr.03-46: The low level for the analog input, default is 10%.
If analog input > Pr.03-45, the multi-function output terminal
operates. If analog input < 03-46, the multi-function output
terminal stops output.
The terminal works when the internal fan warning activates.
12.1-02-19
Descriptions
Status of safety output
Status B (MOx=68)
Short circuit (Close)
Broken circuit (Open)
Broken circuit (Open)