Delta VFD300C43S-HS User Manual page 638

Vector control drive (high speed models)
Table of Contents

Advertisement

Chapter 15 CANopen Overview C2000-HS
ID
Display
No.*
45
48
49
50
51
52
54
55
56
57
Fault code
PG slip error
002DH
(Not supported)
0030H
ACI loss (ACE)
External Fault; when the
multi-function input terminal (EF) is
0031H
active, the AC motor drive stops
output.
Emergency stop; when the
multi-function input terminals MI1 to
0032H
MI6 are active, the AC motor drive
stops output.
External Base Block; when the
multi-function input terminal (B.B.) is
0033H
active, the AC motor drive stops
output.
Keypad is locked after you enter the
0034H
wrong password three times.
Modbus function code error (illegal
0036H
function code)
Modbus data address error [illegal
0037H
data address (00 H–254 H)]
0038H
Modbus data error (illegal data value)
Modbus communication error (data is
0039H
written to read-only address)
15-30
Description
CANopen
CANopen
fault register
fault code
(bit 0–7)
7
7301H
1
FF25H
5
9000H
5
9000H
5
9000H
5
FF26H
4
7500H
4
7500H
4
7500H
4
7500H

Hide quick links:

Advertisement

Table of Contents
loading