Chapter 12 Description of Parameter SettingsC2000-HS
Use this function with Pr. 02-32, Pr. 02-33, Pr. 02-34, Pr. 02-57
and Pr. 02-58.
Refer to the crane function examples below.
Active when motor actual speed is higher than Pr. 02-47.
This function needs to be used with Pr. 06-71–Pr. 06-73
Use this function with external terminal input = 49 (drive enabled)
and external terminal output = 45 (electromagnetic valve
enabled), and then the electromagnetic valve is ON or OFF
according to the status of the drive.
When dEb rises at the master, MO sends a dEb signal to the
slave. Output the message when the master triggers dEb. This
ensures that the slave also triggers dEb. Then slave follows the
deceleration time of the master to stop simultaneously with the
master.
When the drive stops, and the frequency command < Pr. 02-34,
the contact of corresponding multi-function terminal is ON. The
contact is OFF when the brake delay time exceeds Pr. 02-32.
Output when homing action is completed.
12.1-02-17