Delta VFD300C43S-HS User Manual page 222

Vector control drive (high speed models)
Table of Contents

Advertisement

Chapter 11 Summary of Parameter SettingsC2000-HS
Pr.
Parameter Name
00-26
Maximum user-defined value
00-27
User-defined value
00-29
LOCAL / REMOTE mode
Master frequency command
00-30
(HAND) source
Operation command (HAND)
00-31
source
Setting Range
022xh: m3/h
023xh: GPM
024xh: CFM
xxxxh: Hz
0: Disable
0–65535 (when Pr. 00-25 set to no decimal place)
0.0–6553.5 (when Pr. 00-25 set to 1 decimal place)
0.00–655.35 (when Pr. 00-25 set to 2 decimal
places)
0.000–65.535 (when Pr. 00-25 set to 3 decimal
places)
Read only
0: Standard HOA function
1: When switching between local and remote, the
drive stops.
2: When switching between local and remote, the
drive runs with REMOTE settings for frequency
and operation status.
3: When switching between local and remote, the
drive runs with LOCAL settings for frequency and
operation status.
4: When switching between local and remote, the
drive runs with LOCAL settings when switched to
Local and runs with REMOTE settings when
switched to Remote for frequency and operation
status.
0: Digital keypad
1: RS-485 communication
2: External analog input (Pr. 03-00)
3: External UP / DOWN terminal (multi-function
input terminal)
4: Pulse input without direction command
(Pr. 10-16 without direction)
5: Pulse input with direction command (Pr. 10-16)
6: CANopen communication card
8: Communication card (does not include CANopen
card)
0: Digital keypad
1: External terminals.
11-6
Default
0
Read
Only
0
0
0

Hide quick links: