Delta VFD300C43S-HS User Manual page 678

Vector control drive (high speed models)
Table of Contents

Advertisement

Chapter 16 PLC Function ApplicationsC2000-HS
Special
D
PID 1 Feedback selection:
0: Refer to D1204
D1203
1: AVI
2: ACI
3: AUI
D1204 PID 1 Feedback value (0.00%–100.00%)
D1205 PID 1 P value (decimal 2 points)
D1206 PID 1 I value (decimal 2 points)
D1207 PID 1 D value (decimal 2 points)
D1209 PID 1 Max. limit
D1215 PID 1 Calculation (decimal 2 points)
PID2 Mode:
D1220
0: Basic mode
PID 2 Target selection:
0: Refer to D1202
D1221
1: AVI
2: ACI
3: AUI
D1222 PID 2 Target value (0.00%–100.00%)
PID 2 Feedback selection:
0: Refer to D1204
D1223
1: AVI
2: ACI
3: AUI
D1224 PID 2 Feedback value (0.00%–100.00%)
D1225 PID 2 P value (decimal 2 points)
D1226 PID 2 I value (decimal 2 points)
D1227 PID 2 D value (decimal 2 points)
D1229 PID 2 Max. limit
D1235 PID 2 Calculation (decimal 2 points)
Description of Function
16-36
Default
R/W *
1
RW
0
RW
10
RW
1000
RW
0
RW
10000
RW
0
RO
0
RW
0
RW
5000
RW
1
RW
0
RW
10
RW
1000
RW
0
RW
10000
RW
0
RO

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents