Chapter 13 Warning CodesC2000-HS
ID No.
Display on LCM Keypad
105
Action level
Action time
Warning setting parameter
Reset method
Reset condition
Record
Cause
The motor runs in reverse direction
at start
The difference between motor
parameter measured Rr and Rs
value is too large
Insufficient output torque is
dragged to the reverse direction by
the load.
ID No.
Display on LCM Keypad
123
Action level
Action time
Warning setting parameter
Reset method
Reset condition
Record
Cause
Instantaneous power off or low
voltage and unstable/ sudden
heavy load of the power that cause
the voltage drop
Unexpected power off
Warning Name
Estimated speed
Estimated speed is in a reverse direction with motor
reverse (SpdR)
actual running direction
Action and Reset
Software detection
Pr. 10-09
Pr. 10-08
0: Warn and keep operation
1: Warn and coast to stop
2: Warn and ramp to stop
Manual reset
Immediately resets
N/A
Check if the motor is hold when started, or start the motor with speed source.
Normally the Rr value of IM is Rs*0.7. If there is much difference of the
measured value (e.g. Rr=Rs*0.3), proceed the motor parameter auto-tuning
again.
Increase the current limit of Pr. 06-12, so as to increase the output torque.
Warning Name
Deceleration energy
Deceleration energy backup
backup (dEb)
Action and Reset
Software detection
N/A
0: Disable
1: dEb with auto accel./decel., the output frequency will note return after power
reply.
2: dEb with auto accel./decel., the output frequency will return after power reply.
3: dEb low-voltage control, then increase to 350V
stop.
4: dEb high-voltage control of 350V
Manual reset
Immediately resets
N/A
Check the power consumption
Check the power consumption
13-42
Description
Corrective Actions
Description
/700V
DC
/700V
and decelerate to stop
DC
DC
Corrective Actions
and decelerate to
DC