Delta VFD300C43S-HS User Manual page 302

Vector control drive (high speed models)
Table of Contents

Advertisement

Chapter 12 Description of Parameter SettingsC2000-HS
Settings
Functions
5
Reset
6
JOG command
Acceleration /
7
deceleration speed
inhibit
1
and 2
st
8
deceleration time
selection
3
rd
and 4
9
deceleration time
selection
EF Input
10
(EF: External Fault)
Use this terminal to reset the drive after clearing a drive fault.
This function is valid when the source of the operation
command is the external terminals.
The JOG operation executes when the drive stops completely.
While running, you can still change the operation direction, and
the STOP key on the keypad is valid. Once the external terminal
receives the OFF command, the motor stops in the JOG
deceleration time. Refer to Pr.01-20–01-22 for details.
When you enable this function, the drive stops acceleration or
deceleration immediately. After you disable this function, the AC
motor drive starts to accelerate or decelerate from the inhibit
point.
acceleration /
nd
You can select the acceleration and deceleration time of the drive
with this function, or from the digital status of the terminals; there
th
acceleration /
are four acceleration and deceleration selections.
For external fault input. The drive decelerates according to the
Pr. 07-20 setting, and the keypad shows "EF" (it shows the fault
record when an external fault occurs). The drive keeps running
until the fault is cleared (terminal status restored) after RESET.
Descriptions
12.1-02-4

Hide quick links:

Advertisement

Table of Contents
loading