Delta VFD300C43S-HS User Manual page 320

Vector control drive (high speed models)
Table of Contents

Advertisement

Chapter 12 Description of Parameter SettingsC2000-HS
The Width of the Desired Frequency Reached 2
Settings
 The upper limit of setting range is the same as the maximum operating frequency for Pr. 01-00.
 Once the output speed (frequency) reaches the desired speed (frequency), if the corresponding
multi-function output terminal is set to 3–4 (Pr. 02-13, Pr. 02-14, Pr. 02-36, and Pr. 02-37), this
multi-function output terminal is "closed".
02-13,02-14,
02-36,02-37, =4
Brake Delay Time
Settings 0.000–65.000 sec.
 When the AC motor drive runs after the setting delay time of Pr. 02-32, the corresponding
multi-function output terminal (12: mechanical brake release) is "closed". This function must be
used with DC brake.
0.0–1500.0 Hz
H
Fcmd=60Hz
02-24=40Hz
02-25=2Hz
02-22=10Hz
02-23=2Hz
02-13,02-14,
=3
02-36,02-37,
12.1-02-22
Default: 2.0
42Hz
40Hz
38Hz
12Hz
10Hz
8Hz
T
Default: 0.000