Delta VFD300C43S-HS User Manual page 431

Vector control drive (high speed models)
Table of Contents

Advertisement

Example:
STX
Address
Function
Exception code
LRC Check
END
The explanation of exception codes:
Error code
1
2
3
4
Communication Response Delay Time
Settings
 Sets the response delay time after the AC motor drive receives a communication command as
shown in the following.
Communication Main Frequency
Settings
 When you set Pr. 00-20 to 1 (RS-485 serial communication), the AC motor drive saves the last
frequency command into Pr. 09-10 when there is abnormal power off or momentary power loss.
After the drive reboots when power is restored, it checks the frequency in Pr. 09-10 if there is no
new frequency command is input. When a frequency command of RS-485 changes (the
frequency command source must be set as Modbus), this parameter also changes.
Block Transfer 1
Block Transfer 2
Block Transfer 3
Block Transfer 4
Block Transfer 5
Block Transfer 6
Block Transfer 7
Block Transfer 8
Block Transfer 9
ASCII mode:
':'
'0'
'1'
'8'
'6'
'0'
'2'
'7'
'7'
CR
LF
Function code is not supported or unrecognized.
Address is not supported or unrecognized.
Data is not correct or unrecognized.
Fail to execute this function code
0.0–200.0ms
0.0–1500.0 Hz
Chapter 12 Description of Parameter SettingsC2000-HS
Address
Function
Exception code
CRC Check Low
CRC Check High
Explanation
12.1-09-12
RTU mode:
01H
86H
02H
C3H
A1H
Default: 2.0
Default: 600.0