Delta VFD300C43S-HS User Manual page 363

Vector control drive (high speed models)
Table of Contents

Advertisement

Magnetizing Inductance (Lm) for Induction Motor 2
Stator Inductance (Lx) for Induction Motor 2
Settings
Induction Motor 1/ 2 Selection
Settings
 Sets the motor currently operated by the AC motor drive.
Frequency for Y-connection / ∆-connection Switch for an Induction Motor
Settings
Y-connection / ∆-connection Switch for Induction Motor
Settings
Delay Time for Y-connection / ∆-connection Switch for an Induction Motor
Settings
 You can apply Pr. 05-23–Pr. 05-25 in a wide range of motors, and the motor coil executes the
Y-connection / -connection switch as required. The wide range motors are related to the motor
design. In general, the motor has higher torque with low speed Y-connection, and has higher
speed with high speed -connection).
 Pr. 05-24 enables and disables the switch of Y-connection / -connection.
 When you set Pr. 05-24 as 1, the drive uses the Pr. 05-23 setting and current motor frequency,
and switches the current motor to Y-connection or -connection. You can switch the relevant
motor parameter settings simultaneously.
 Pr. 05-25 sets the switch delay time of Y-connection / -connection.
 When the output frequency reaches Y-connection / -connection switch frequency, the drive
delays according to Pr. 05-25 before activating the multi-function output terminals.
0.0–6553.5 mH
1: Motor 1
2: Motor 2
0.0–1500.0 Hz
0: Disable
1: Enable
0.000–60.000 sec.
12.1-05-4
Chapter 12 Description of Parameter SettingsC2000-HS
Default: 0.0
Default: 1
Default: 600.0
Default: 0
Default: 0.200