Delta VFD300C43S-HS User Manual page 303

Vector control drive (high speed models)
Table of Contents

Advertisement

Settings
Functions
B.B input from external
11
(B.B: Base Block)
Output Stop
12
(Output pause)
Cancel the setting for
13
auto-acceleration /
auto-deceleration time
Switch between motor 1
14
and motor 2
Rotating speed
15
command from AVI
Rotating speed
16
command from ACI
Rotating speed
17
command form AUI
Forced to stop
18
(Pr. 07-20)
19
Digital Up command
20
Digital Down command
21
PID function disabled
Clear the counter
22
Chapter 12 Description of Parameter SettingsC2000-HS
ON: the output of the drive stops immediately. The motor is in
free run and the keypad displays the B.B. signal. Refer to
Pr.07-08 for details.
When the switch is ON, output of the drive stops immediately and
the motor is in free run status. The drive is in output waiting
status until the switch is turned to OFF, and then the drive restarts
and runs to the current setting frequency.
Set Pr.01-44 to one of the 01–04 setting modes before using this
function. When this function is enabled, OFF is for auto mode
and ON is for linear acceleration / deceleration.
ON: use parameters for motor 2
OFF: use parameters for motor 1
ON: force the source of the frequency to be AVI. (If the rotating
speed commands are set to AVI, ACI and AUI at the same time,
the priority is AVI>ACI>AUI)
ON: force the source of the frequency to be ACI. (If the rotating
speed commands are set to AVI, ACI and AUI at the same time.
The priority is AVI>ACI>AUI)
ON: force the source of the frequency to be AUI. (If the rotating
speed commands are set to AVI, ACI and AUI at the same time.
The priority is AVI>ACI>AUI)
ON: the drive ramps to stop according to the Pr.07-20 setting.
ON: the frequency of the drive increases or decreases by one
unit. If this function remains ON continuously, the frequency
increases or decreases according to Pr.02-09 / Pr.02-10.
The Frequency command returns to zero when the drive stops,
and the displayed frequency is 0.0 Hz. If you select Pr.11-00, bit
7 = 1, the frequency is not saved.
ON: the PID function is disabled.
ON: the current counter value is cleared and displays 0. The
drive counts up when this function is disabled.
12.1-02-5
Descriptions